50℃~300℃
  • Heating Circulator UC series with function from high temperature to cooling process, from 300℃~50℃.
  • Equipped with heating cooling container, with large heat transfer area, fast heat-up and cool-down, small heat transfer oil demand.
  • the heating cooling circulator Can heat-up and cool-down continuously.
  • The whole cycle is full closed,there is no oil mist at high temperature, heat transfer oil can not be oxidized and browning.
  • With function of internal PT100 for correcting internal circulation.
  • The whole system is closed with expansion tank, the expansion tank and liquid circulation are thermal insulation, do not participate in liquid circulation, regardless of high or low temperature, the medium in expansion tank is limited to 60℃..
LNEYA application
LNEYA application
Technical Parameters of Dynamic Temp. Control System:

Model

Temp. Range ℃

Heating  kw

Cooling  KW  AT  ℃

Flow pressure

Dimensions CM

300

200

100

65

UC-3530

+50~+300

3.5

3.5

3.5

2.8

1

35

2

40*60*115

UC-5530

+50~+300

5.5

5.5

5.5

4

1.8

50

2

50*68*125

UC-7530

+50~+300

7.5

7.5

7.5

5

2.2

75

2

55*68*145

UC-A1030

+50~+300

10

10

10

7

3

110

2.5

55*68*145

UC-A1530

+50~+300

15

15

15

12

5

110

2.5

65*70*175

UC-A2530

+50~+300

25

25

25

20

8.5

150

2.5

75*80*185

UC-A3830

+50~+300

38

38

38

30

12

200

2.5

100*95*175

UC-A6030

+50~+300

60

60

60

48

19

250

2.5

150*125*205

UC-A9530

+50~+300

95

95

95

76

30

400

2.5

205*145*205

UC-A13030

+50~+300

130

130

130

100

40

400

2.5

205*145*205

UC-A20030

+50~+300

200

200

200

160

64

600

3

275*145*225

LNEYA application

The characteristics of Heating and Cooling Circulator

The entire liquid circulation of Heating cooling cycle (50℃~300℃ ) is airtight, with expansion containers. No matter the temperature of the liquid circulation is high-temperature or the temperature of the media in the low-temperature expansion containers lower than 60℃, the expansion containers and liquid circulation is adiabatic, not involved in the liquid cycle, but the mechanical connection.

The whole liquid circulation is a closed system, no water vapor absorption at low temperature, no oil mist at high temperature, for the heat conduction oil has a wide range of working temperature. There are no mechanical and electronic valves in the whole circulatory system.

Wide range of operating temperature with heating refrigeration function. The maximum temperature range is between -50℃~250℃.
The controller with 2 LED displays can display both the temperature setting and the actual value, as well as the over-temperature alarm value. It has the features of efficiency and fastness, and also easy to fill the liquid. To ensure the rapid cooling at high temperature, it can continuously control the temperature at 250℃ to -50℃.

The circulation management is completely closed, without oil mist and water absorption, which ensures the safety of experiment and the life of heat conducting liquid. The refrigeration adopts the American Goulen compressor and circulating pump, stable and reliable.

It has the function of self-diagnosis, overload protection of chiller, high pressure switch, overload relay, thermal protection device and so on. The temperature of heat conduction medium is controlled and the whole cooling process adopts the same heat conduction medium. The high-lift pump meets the needs of the long-distance transmission of heat conduction medium.
Related Products
  • Thermostatic Bath SC -50 /-100 ℃

    Thermostatic Bath SC -50 /-100 ℃

    January 11, 2018InformationRefrigerationSystem 1.Singlecompressorcascaderefrigerationtechnology. 2.Fastercoolingspeed,energysaving,highefficient,lownoise. 3.Famousbrandcompressor.view
  • Chiller Refrigeration System SUNDI-320/420W/430W

    Chiller Refrigeration System SUNDI-320/420W/430W

    January 11, 2018Applied to the glass reactor,metal reactor,bioreactor for cooling&heating and thermostatic control,particularly suitable for controlling the required heat or heat release in the process of reaction.view
  • Low Temperature Chiller LN -60℃~-10℃

    Low Temperature Chiller LN -60℃~-10℃

    January 11, 2018InformationLow circulator, Low temp circulator, Constant temp circulator, Low circulator, Low temp, circulation bath, Circulators bath, Circulation bath, Circulators, Chiller, Cooling circulators, Cooling bath circulators, Cooling thermostat, Refrigeratioview
Leave a Message Email Us

we will contact you within 24 hours.

x
Want some help from our team? LNEYA is dynamic temperature control equipment leader in China. We’ll contact you very soon.
Brilliant Features of LNEYA Dynamic Temperature Control System:
Contact us and we will offer the most suitable solution for you.
  • TEL:+ 86 510 82303782
  • FAX:+ 86 510 88587187
  • EMAIL:sales@cnzlj.com
  • ADDRESS:No.10, Zhenfa No.1 Road, Shuofang Street, New District, Wuxi, Jiangsu, China