Technical Parameters:

Low circulator, Low temp circulator, Constant temp circulator, Low circulator, Low temp, circulation bath, Circulators bath, Circulation bath, Circulators, Chiller, Cooling circulators, Cooling bath circulators, Cooling thermostat, Refrigeration bath circulators, Refrigeration circulator, Refrigeration thermostats, Refrigeration bath circulator, Low temp freezer, Freezer, Low freezer, Low chiller, Freezer chiller, Cold trap, Immersion cooler, Low temp bath, Bath thermostats.

Model LN-6W LN-10W LN-15W LN-20W LN-30W LN-40W LN-60W LN-90W LN-120W LN-180W
Temp. range -60°C~ -10°C
Cooling capacity 12kw 20kw 30kw 40kw 60kw 80kw 120kw 180kw 240kw 360kw
At -40°C Kcal/h 10320 17200 25800 34400 51600 68800 103200 154800 206400 309600
Cooling capacity 6kw 10kw 15kw 20kw 30kw 40kw 60kw 90kw 120kw 180kw
At -55°C Kcal/h 5160 8600 12900 17200 25800 344000 51600 77400 103200 154800
Circulation pump 6.6m³/h 9m³/h 15m³/h 15m³/h 25m³/h 25m³/h 25m³/h 35m³/h 35m³/h 50m³/h
2.5bar 2.5bar 2.5bar 2.5bar 2.5bar 2.5bar 2.5bar 2.5bar 2.5bar 2.5bar
Connection size DN-32
PN-10
DN-40
PN-10
DN-40
PN-10
DN-40
PN-10
DN-50
PN-10
DN-50
PN-10
DN-50
PN-10
DN-65
PN-10
DN-65
PN-10
DN-80
PN-10
Cooling water  30 DEG 10m³/h 14m³/h 20m³/h 25m³/h 30m³/h 35m³/h 50m³/h 70m³/h 90m³/h 120m³/h
Cool storage tank (optional) 200L 350L 500L 750L 1000L 1200L 1500L 2200L 3000L 4000L
Expansion tank (optional) 100L 175L 250L 350L 500L 600L 750L 1000L 1350L 1800L
Compressor Standard: Dorin semi-closed compressor Standard: Hanbell screw compressor
Optional: Bitzer screw compressor
Operation panel 7 inch color touch screen display input, temperature curve record.
Control system Standard: single chip microcomputer controller, position setting to open refrigeration
and close refrigeration temperature difference.
Optional: Siemens S7 series PLC and module.
Circulation system The whole system is fully closed system. The heat conduction medium does not absorb
the water in the air and will be replenished automatically at low temperature. The system
will not increase the pressure due to the high temperature in the operation.
Circulation pump Wuxi guanya tube type centrifugal pump.
Evaporator Standard: Brazing plate heat exchanger.
Optional: stainless steel tube heat exchanger.
Condenser Shell and tube type water cooled condenser.
Intermediate heat exchanger Plate heat exchanger.
Drying filter Emerson
Dry filter element Emerson
Expansion valve Emerson
Refrigeration solenoid valve Emerson
Oil separator Emerson
Pressure protector Emerson
Reservoir
Sight glasses Standard: Sanhua  Optional: Danfoss
Refrigeration ball valve Standard: Sanhua  Optional: Danfoss
Electricity Schneider electric contact, schneider intermediate relay.
Refrigerant R404A
Secondaryrefrigerant Non-corrosive liquid, ethanol aqueous solution, thermal conductivity oil, etc.
Security and protection High pressure protection, water break protection, current protection, leakage protection,
continuous and broken phase protection, high temperature protection, sensor fault alarm,
low level alarm and other multiple security protection.
Level indicator Glass level indication.
Piping material SUS304
Expansion tank volume SUS304
Shell material Channel steel + square pipe + cold rolled steel
Dimension cm 180*120
*175
205*145
*175
205*145
*175
205*145
*175
235*145
*175
245*145
*205
350*150
*235
350*150
*235
400*180
*235
450*200
*235
Power supply max 380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
380V
50HZ
10~15kw 14~20kw 21~30kw 24.5~35kw 36.5~60kw 56~80kw 85~120kw 112~160kw 160~240kw 252~360kw
Noise Within 75db Within 80db Within 90db
Weight 850kg 1000kg 1200kg 1450kg 2000kg 2400kg 3000kg 3600kg 4200kg 5600kg
We know that the low temperature chillers are complicated equipment. Even the switch process, if not according to the standard of operation or with no special maintenance, will inevitably lead to a decline in the refrigeration efficiency of the low temperature chillers and will greatly reduce the service life of the them. Here, we will talk about major attention matters when enterprises use low temperature chillers!

1. Refrigerant leakage

Refrigerant leakage will not only affect the refrigeration efficiency of low temperature chillers, but also affect the health of people in and out of the engine room, so the issue of refrigerant leakage must be noted.

2. Pay attention to the load of the low temperature chillers

The large load of low temperature chillers, or overload phenomenon which is more than the rated load, will bring about serious problems including refrigeration efficiency decline, bigger noise,  bigger vibration amplitude, excessive consumption of resources, decline in service life and so on which need to pay attention to!

3. Temperature and pressure

It can be said that the parameters related to temperature and pressure are the most important parameters of low temperature chillers. Enterprises should pay attention to the parameters related to the temperature and pressure of the low temperature chillers, and solve them in time, so as to avoid affecting the normal operation of the low temperature chillers.

Paying attention to the points mentioned above has extraordinary importance for extending the service life of low temperature chillers ,and improving the refrigeration efficiency and the use safety of low temperature chillers.
Related Products
  • Salt Fog Test Chamber

    Salt Fog Test Chamber

    April 8, 20181. Scope of application.With the rapid development of modern industrial technology, the application fields of all kinds of electronic and electroplating products are becoming more and more extensive, ...view
  • Heating Circulator UST-series

    Heating Circulator UST-series

    January 11, 2018InformationWidely used in petrochemical, chemical, pharmaceutical, bioengineering, life science, Light industry and food,Industry, sample testing and so on, provide a high-precision constant temperature liquid environment.view
  • Lab Water Chiller SUNDI -60℃~300℃

    Lab Water Chiller SUNDI -60℃~300℃

    April 10, 2018Chillers of Guanya Refrigeration are various in temperature range like -60℃ ~ 250℃. You can find one you are in need. Call us by +86 510 82303782.view
Leave a Message Email Us

we will contact you within 24 hours.

x
Want some help from our team? LNEYA is dynamic temperature control equipment leader in China. We’ll contact you very soon.
Brilliant Features of LNEYA Dynamic Temperature Control System:
Contact us and we will offer the most suitable solution for you.
  • TEL:+ 86 510 82303782
  • FAX:+ 86 510 88587187
  • EMAIL:sales@cnzlj.com
  • ADDRESS:No.10, Zhenfa No.1 Road, Shuofang Street, New District, Wuxi, Jiangsu, China