Search the whole station

SUNDI  -25℃~200℃
SUNDI  -25℃~200℃
SUNDI  -25℃~200℃
SUNDI  -25℃~200℃
SUNDI  -25℃~200℃

SUNDI -25℃~200℃

Cooling Heating System of reactor and material
  • Cooling capacity1kW~200kW
  • Heating Power2.5kW~200kW
  • Power range4kW~260kW
  • Medium accuracy±0.5℃~±1℃
  • Material accuracy±1℃~±1.5℃
  • RefrigerantR404A
  • Weight115KG~2150KG

Product data download

  • manual.pdf

Product Description

● Working temperatures from -120°C to +350°C
● Previously unachievable performance
●Intelligent temperature control
● Maximum process stability and reproducibility
● Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
● High cooling power from 0.5 to 1200kW
● Large temperature range without fluid change
● Closed system, extend thermal fluid lifetime
● 7-inch, 10-inch color TFT touch screen display
● Comprehensive warning and safety functions
● Rapid cooling down from high temperature (from 300 °C)
● Use magnetic drive pump, solve the circulation pump leakage

Configuration Details

Model SUNDI-225
SUNDI-225W
SUNDI-235
SUNDI-235W
SUNDI-255
SUNDI-255W
SUNDI-275
SUNDI-275W
SUNDI-2A10
SUNDI-2A10W
SUNDI-2A15
SUNDI-2A15W
SUNDI-2A25
SUNDI-2A25W
SUNDI-2A38W SUNDI-2A60W SUNDI-2A95W SUNDI-2A130W SUNDI-2A200W
Temp. range -25℃~+200℃
Control Mode Feedback PID + Our special dynamic control calculation, PLC controller
Temp. control Process temp. control and jacket temp. control model
Temp. difference Set or control the temperature difference between jacket oil and raw material process
Program Editor 5 programs, each program can edit 40 steps.
Communication Portocol MODBUS RTU Protocol, RS485 interface
Material temp. feedback PT100 OR 4~20mA or communication(normal: PT100)
Temp. feedback The temp. of three points: the inlet and outlet of equipment,reactor material temp.(external temp. sensor)
Medium temp. acccuracy ±0.5℃   ±1℃
Material temp. accuracy ±1℃ ±1.5℃  
Heating power kW 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
Cooling capacity kW at 200℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  100℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  50℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  20℃ 2.5 3.5 5.5 7.5 10 15 25 38 60 95 130 200
  -5℃ 2 3 4.5 6.6 8 12 19 30 46 70 80 125
  -20℃ 1 1.8 2.8 3.8 4.6 7 12 16 22 32 43 65
Circulation pump max
L/min bar
20 35 35 50 50 110 150 200 250 400 400 600
    1 1.2 1.2 1.2 1.2 1.5 1.5 1.5 2.5 2.5 2.5 2.5
Compressor Mitsubishi Emerson copeland vortex flexible Dorin seni-closed compressor
Expansion valve Emerson thermal expansion valve/danfoss thermal expansion valve.
Evaporator Plate heat exchanger
Operation Panel 7-inch touch screen,show temp curve\EXCEL data output
Safety protection Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
Refrigerant R404A,optional: R448A/R125
Connection size ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1 Z G1 DN32 PN10 DN40 PN10 DN50 PN10 DN65 PN10 DN65 PN10 DN80 PN10
Water-cooled type W(cooling water@20℃) 600L/H
1.5bar~4bar
800L/H
1.5bar~4bar
1000L/H
1.5bar~4bar
1200L/H
1.5bar~4bar
1600L/H
1.5bar~4bar
2200L/H
1.5bar~4bar
6m³/H
1.5bar~4bar
10m³/H
1.5bar~4bar
14m³/H
1.5bar~4bar
20m³/H
1.5bar~4bar
28m³/H
1.5bar~4bar
36m³/H
1.5bar~4bar
Dimension(water type)cm 40*70*130 45*70*160 45*700*160 55*700*175 65*85*185 70*85*185 80*120*185 150*100*185 200*145*205 200*145*205 250*145*225 300*160*225
Weight kg 115 165 185 230 280 300 550 750 1000 1250 1580 2150
Power 380V 50HZ 4kW 5.6kW 8kW 11kW 14kW 21kW 35kW 54kW 81kW 126kW 165kW 260kW

Working Principle

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Click online message to inquire about product details
Send us a message about the product
Send us a message about the product
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

You may also be interested in these products

loading…

已经是到最后一篇内容了!

Expand more!