Usage Details of High and Low Temperature Environmental Chambers

The enterprise users must have a certain understanding of the functions of the high and low-temperature environmental chamber after using them for a long time, but something detail of the high and low-temperature environmental chamber may still not be paid attention to, so the technology department of Wuxi LNEYA has specially reorganized the related matters of attention for everyone.

Professional manufacturer of high and low-temperature environmental chambers for sale

When delivering, the tilted angle of the high and low-temperature environmental chamber should not exceed 30°. When carrying, keep the body of the high and low-temperature environmental chamber vertically, do not place it inversely or horizontally. Besides, dragging the door handle or the condenser are prohibited, otherwise, the equipment may be damaged.

The high and low-temperature environmental chamber should be electrified regularly every month during the lengthy shutdown period, and the power-on time should be more than 1h.

Professional manufacturers of high and low-temperature environmental chamber insist on taking out the test samples after each test and wipe the workroom wall of the environmental chamber to keep the inner box clean.

Cleaning and balance of the circulating blade and condenser fan: Similar to that of the cleaning evaporator, because the working environment of the environmental chamber is different, a lot of small particles like dust will condense on the circulating blade and condenser fan. Hence, they should be cleaned regularly.

The power supply voltage of the high and low-temperature environmental chamber fluctuations, such as repeated power failure. In this case, it is suggested to suspend the use of high and low-temperature environmental chamber and close the power supply to prevent the burning of the compressor. Do not start the compressor immediately after the shutdown of the high and low-temperature environmental chamber. It should be stopped for 2-5 minutes before restarting.

The condenser of the high and low-temperature environmental chamber should be cleaned every three months. The condensing fan should be regularly overhauled and the condenser should be cleaned and dedusted so as to ensure its good ventilation and heat transfer performance.

High and low-temperature environmental chamber should be placed in a well-ventilated position with low humidity and smooth ground, 60 ~ 70 cm of use and maintenance space should be left around.

During the operation of high and low-temperature environmental chamber, the frequency of door opening should be minimized and the spillage of cold air should be reduced.

The usage details of high and low-temperature environmental chamber should be used by enterprise users in daily use.

Related News
  • How To Choose The Screw Type Water-Cooled Chiller

    How To Choose The Screw Type Water-Cooled Chiller

    July 4, 2018Compared with the similar chillers, the screw type water-cooled chiller has many advantages. We as one of the top chiller manufacturers share you more.1. The temperature of the heat conducting liquid ...view
  • The Application of Industrial Chillers

    The Application of Industrial Chillers

    July 4, 2018The chiller machine is needed in a lot of industries, basically chemical, medical, pharmaceutical industries are involved, then what industry can Wuxi Lneya chiller meet in the end? It is known that ...view
  • Daily Maintenance of Low Temperature Freezer

    Daily Maintenance of Low Temperature Freezer

    August 9, 2018Low temperature freezer, which is also called industrial refrigerator, is mainly used for industrial cold treatment, the increase of wear-resisting property and friction of metals. Guanya Refrigeratio...view
  • Cautions To Use The Water Cooling Unit

    Cautions To Use The Water Cooling Unit

    May 22, 2018Cautions To Use The Water Cooling UnitManufacturers now use recycled water to save costs. However, many manufacturers put circulating water of the whole plant in one water network, which will lead to...view
  • Knowledge Sharing Of Chiller Selection And Maintenance

    Knowledge Sharing Of Chiller Selection And Maintenance

    July 4, 2018Chillers can be used in a lot of industry, but who is the better low temperature chiller manufacturer in top chiller manufacturers?Let me tell you. The choice of own model and the maintenance are also...view
  • The Prospect of the Supporting Heating Cooling Circulator

    The Prospect of the Supporting Heating Cooling Circulator

    July 4, 2018With the continuous development of enterprises, as a matching equipment used in the lad, the heating cooling circulator which acts as a brand for manufacturers will be prosperous in the market, accele...view
x
Want some help from our team? LNEYA is dynamic temperature control equipment leader in China. We’ll contact you very soon.
Brilliant Features of LNEYA Dynamic Temperature Control System:
Contact us and we will offer the most suitable solution for you.
  • TEL:+ 86 510 82303782
  • FAX:+ 86 510 88587187
  • EMAIL:sales@cnzlj.com
  • ADDRESS:No.10, Zhenfa No.1 Road, Shuofang Street, New District, Wuxi, Jiangsu, China