FL-WD 5℃~30℃

FL-WD 5℃~30℃

Evaporative condensation (dual compressors) chiller
  • Cooling Power60kW~427kW
  • Power Supply3N/380V/50Hz
  • Weight1320kG~6640kG

Product data download

  • manual.pdf
Send us a message and we will contact you as soon as possible
Send us a message and we will contact you as soon as possible
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Product Description

LNEYA applicationLNEYA application

1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.
2.Due to continuous updating of product technology, the above data is subject to change without prior notice.
3.In addition to the listed product models, our company can customize non-standard units according to customer requirements.

why choose lneya

Model FL-WD 280 400 500 600 720 840 910 1008 1160 1260 1340 1420 1530 1700 1940
Cooling
capacity
KW 272 388 485 597 715 833 906 1008 1152 1268 1342 1416 1528 1700 1940
Kcal/hr
*10³
234 394 417 513 615 716 779 867 991 1090 1154 1218 1314 1462 1668
Power   3N/380V/50Hz
Cooling
input
power
KW 61 86 108 130 155 180 193 215 240 265 277 290 318 355 400
Compressor Form semi-closed double screw compressor
Heat
control
range
0-25-37.5-50-625-75-87.5-100(12.5% segmentation control)
Chilled
water
Form Dry, overflow or falling film heat exchanger
Chilled
water
volume
T/H
47 67 83 102 123 143 155 173 197 217 230 243 262 291 333
Water
pressure
drop KPa
44 49 49 50 54 56 58 72 73 73 74 74 75 75 76
Connection
size
DN-80 DN-100 DN-125 DN-150 DN-200
cooling
water
Form horizontal and tube sheel type
cooling
water
volume
T/H
57 81 100 123 148 172 187 208 237 260 275 289 315 351 396
Water
pressure
drop KPa
44 45 46 49 55 56 58 65 74 74 72 74 76 76 76
Connection
size
DN-80 DN-100 2-DN-80 2-DN-100 2-DN-125 2-DN-150
Security
device
  High and low voltage protection, anti-icing, heat release protection (double), safety valve,
overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc.
Refrigerant Charge
Kg
34 53 68 84 99 121 134 149 165 188 199 205 219 235 250
Dimension Length
mm
3200 3235 3250 3520 3810 3810 3810 3830 3890 3900 3900 3950 3970 4870 4870
Width
mm
945 1100 1100 1300 1300 1300 1300 1300 1500 1500 1500 1500 1500 1600 1600
Height
mm
1400 1420 1610 1755 1950 1975 1985 2050 2185 2185 2200 2200 2200 2250 2250
Unit
weight
Kg 1650 2300 2400 3000 3500 3800 4000 4500 5700 6200 6300 6700 7200 7900 8300
Working
weight
Kg 1900 2550 2700 3500 4000 4350 4600 5050 6300 6800 6900 7400 7900 8600 9000