LC-WS -25℃~5℃

LC-WS -25℃~5℃

-25 degree single compressor screw chiller
  • Cooling Power27kW~238kW
  • Power Supply3N/380V/50Hz
  • Weight850kG~4345kG

Product data download

Click online message to inquire about product details
Send us a message and we will contact you as soon as possible
Send us a message and we will contact you as soon as possible
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Product Description

LNEYA application

1.The standard design conditions are: chilled water:outlet water temperature 7 ° C, return water temperature 12 ° C; condensing temperature 40 ° C.
2.Due to continuous updating of product technology, the above data is subject to change without prior notice.
3.In addition to the listed product models, our company can customize non-standard units according to customer requirements.

Model LC-WS 100 140 180 200 260 310 340 410 470 510 620 710 750 830 930
Cooling
capacity-15℃
KW 48 64 83 92 124 151 166 197 234 247 305 354 389 418 467
Kcal/hr
*10³
41 55 71 79 107 130 143 169 201 212 263 304 335 360 401
Cooling
capacity
-20℃
KW 39 52 68 75 101 123 135 160 191 202 249 289 317 341 380
Kcal/hr
*10³
34 45 59 65 87 106 116 138 164 174 214 249 273 293 327
Power   3N/380V/50HZ
Cooling
input
power
KW 27 35 45 50 66 79 86 104 122 129 158 182 203 216 238
Compressor Form semi-closed double screw compressor
Heat
control
range
0~25~37.5~50~62.5~75~87.5~100(12.5% segmentation control)
Chilled
water
Form Dry, overflow or falling film heat exchanger
Chilled
water
volume
T/H
18 23 27 33 42 51 60 67 79 87 101 113 128 146 160
Water
pressure
drop
KPa
49 60 73
Connection
size
DN65 DN80 DN100 DN125 DN150
cooling
water
Form horizontal and tube sheel type
cooling
water
volume
T/H
25 28 33 41 53 62 72 80 107 118 136 150 171 198 213
Water
pressure
drop
KPa
45
Connection
size
DN65 DN80 DN100 DN125 DN150
Security
device
  High and low voltage protection, anti-icing, heat release protection (double), safety valve,
overload protection, under-phase, reverse phase, under voltage, over voltage, water flow protection, etc.
Refrigerant Charge
Kg
23 30 35 44 48 55 58 61 75 85 90 115 133 155 165
Dimension Length
mm
2500 2585 2635 2635 3100 3130 3130 3135 3135 3135 3135 3275 3300 3300 3668
Width
mm
850 900 900 900 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100
Height
mm
1300 1335 1335 1428 1428 1570 1680 1776 1800 1800 2000 2020 2070 2100 2120
Unit
weight
kg 850 850 1050 1270 1430 1740 1850 2480 2600 2870 3200 3400 3600 3850 4345
Working
weight
kg 900 900 1100 1420 1580 1890 2050 2580 2800 3120 3500 3700 3900 4150 4640