Wuxi Guanya Refrigeration technology co., ltd
Tel: + 86 510 82303782
E-mail: sales@cnzlj.com
Add: No.10, Zhenfa No.1 Road, Shuofang Street, New District, Wuxi, Jiangsu, China
code chat
Lab Water Chiller SUNDI -60℃~300℃

Lab Water Chiller SUNDI -60℃~300℃

  • Lab Water Chiller SUNDI -60℃~300℃
  • Dynamic Temp Control Systems-2.jpg
  • Dynamic Temp Control Systems-1.jpg
Lab Water Chiller SUNDI -60℃~300℃
  • Product Description
  • System Introduce
  • Technical Parameter
-60℃~300℃
A fully closed piping design, high efficiency plate heat exchanger used to reduce the demand   for the thermal fluid utilization while providing the system to achieve the rapid ups and downs in temperature The whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical connection, regardless of the temperature is a high temperature or low temperature, the tank temperature is limited to 60℃. Therefore, during the process the risk of imbibing and volatilization of the heat conducting medium is reduced. There following advantages for the user.

type

Temp range℃

Heating  KW

Cooling capacity  KW  AT  ℃

Flow/pressure
L/min bar

Outside size

power
KW

300

100

20

-20

-40

-55

SUNDI-655WV

-60~+300

5.5

5.5

5.5

5.5

4.8

2.3

0.75

50

2

550*680*1450

10kw

SUNDI-675WV

-60~+300

7.5

7.5

7.5

7.5

6

3.1

0.9

75

2

650*700*1750

14kw

SUNDI-6A10WV

-60~+300

10

10

10

10

8.2

4.8

1.5

110

2.5

750*750*1850

18kw

SUNDI-6A15WV

-60~+300

15

15

15

15

12

7.8

2.8

110

2.5

1000*950*1750

26kw

SUNDI-6A25WV

-60~+300

25

25

25

25

25

18

6

150

2.5

1500*1250*2050

40kw

Typical application of refrigeration heating temperature control system

Dynamic thermostatic control of cold and heat source of high pressure reaction kettle, dynamic thermostatic control of double layer glass reaction kettle, and dynamic thermostatic control of cold and hot source of double-layer reactor.

Microchannel reactor thermostatic control, small temperature control system, steam - feeding system temperature control, material low temperature aging test.
The thermostatic control of the combined chemical cold source heat source, the cooling heating of the semiconductor equipment and the heating temperature of the vacuum chamber are controlled.

Advantages and functions of temperature control system of refrigeration

Temperature range from 120 to 350, performance superior, unique, high - precision, intelligent temperature control.
High cooling power from 0.5 to 1200kW, highest production stability and repeatable results.
Multi-function alarm system and safety function, use plate heat exchanger, tube type heater to increase heating and cooling rate.
7-inch and 10-inch color TFT touch screen graphics display, use magnetic drive pump, no re-seal leakage problem.
Full airtight system, extended thermal conductivity liquid life, very wide temperature range, no need to change liquid media.
Ultra-high temperature cooling technology can be cooled directly from 300 degrees of high temperature.
The principle and the function has many advantages to using staff: because only expansion of cavity in the body heat conduction medium contact with oxygen in the air (and expansion tank temperature at room temperature to 60 degrees), can achieve lower heat conduction medium absorbed by oxidation and the risk of air moisture.
No heat conduction medium evaporates at high temperature, and it can be achieved -80 ~ 190 degrees, -70 ~ 220 degrees, -88 ~ 170 degrees, -55 ~ 250 degrees, -30 ~ 300 degree continuous temperature control without pressurization.


Adopt full closed pipe design, adopt high efficiency plate heat exchanger, reducing the demand for heat conduction liquid, improve the heat utilization rate of the system, reach the rapid lifting temperature.Thermal conductive medium in a closed system, with a container, expand the heat-conducting medium not participate in circulation in the container, whether high or low temperatures, expansion tank temperature to room temperature to 60 degrees, can reduce the heat conduction medium in running the risk of absorbing the moisture and volatile.

Type

SUNDI/UST series

Control Mode

Feedback PID + Our special dynamic control calculation, Lneya PLC controller

Temp.control

Material reaction temp.control mode and jacket temp.control mode

Program Editor

10 programs, each program can edit 45 steps.

Communication Portocol

MODBUS RTU Protocol,RS485 interface

Optional  Ethernet interface/R232 interface

Temp.feedback

The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor

Material temp. feedback

Material temp. feedback:PT100 or 4~20mA or communication given

Temp.feedback:PT100

Temp. difference

Set or control oil outlet temp and reactor material temp. difference

Set or control equipment liquid inlet temp. And liquid outlet temp. Difference( keep system safe)

Material temp.accuracy

±1℃ (sometimes ±0.5℃)

Thermal medium temp. accuracy

±0.5℃

Closed circulation system

The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.

heating

Heating max output power

The heater has triple protection and independent temperature limiter to ensure the safety of heating system.

The power is greater than 15KW with a voltage regulator, and the heating power output control adopts 4-20ma linear control.

Cooling capacity

The power of taking away the heat at different temperature

Circulation flow rate and pressure

Lower than 75L/min, use Lneya Magnetic pump

Higher than 75L/min use Ultra wide temperature high energy efficiency centrifugal pump.

Pressure selection: 2bar 3bar 5bar 8bar(small power equipment can not customize)

The greater the pressure, the greater the power of the motor, which will increase the system load and reduce the cooling capacity of the system.

compressor

Different type different brand compress

Mitsubishi, skop, Emerson, Danfoss, Italy Dorin, German blog, bizell, French Tecumseh.

evaporator

KAORI Plate heat exchanger

Oil separator

Emerson/Lneya

Drying filter

danfoss/Emerson

Shock tube

CASTEL/packless

voltage-controlled

danfoss/Emerson/fengsheng

Expansion valve

Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve.

Select different expansion valves with different temperature and cooling capacity.

Operation panel

Lneya 7-inch touch screen,show temp curve\EXCEL data output

Optional Siemens explosion - proof touch screen.(Place the operation panel outside the site area.)

optional GMP, FDA operation and record module (operator use record, data record, alarm record, etc.)

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.

refrigerant

R-404A / R404A R23 mixture/ R404A R23 R14 mixture

interface size

G1/2、G3/4、G1、DN25 DN32 DN40 DN50 DN65 DN80 DN100(PN10 RF)

Water-cooling W

 With W is water cooled type, lower than -60 degree equipment, you need use 7-25 degree cooled water

Water cooled condenser.

Tube heat exchanger, plate heat exchanger, tube condenser.

packless、sheng、KAORI、JINDIAN、XIAOLING etc

power

AC 380V 50HZ Three-phase five-wire system.  Small power 220V 50HZ single phase

Optional 460V 60HZ、220V 60HZ three-phase  

Shell material

Standard shellSUS 304,optionalspraying plastics (color 7035)

Isolation of explosion-proof

optioanl(EXdIIBT4)   

Lneya explosion-proof product installation license number.:PCEC-2017-B025

Positive pressure explosion-proof

optioanl(EXPXdmbIICT4) The positive pressure system must be water-cooled type

Lneya explosion-proof product installation license number:PCEC-2017-B025

Self pressurizing system

Optional self-pressurized 3bar system, the temperature of the system can be expanded, the expansion tank is normal pressure.

KDOC-80 can be used in a pressurized system with a maximum temperature of 250 degrees (-85 degree ~ 250 degree).

KDOC-220 can be used in the self-pressurized system with maximum temperature to 320 degrees (-50 degree ~ 320 degree).

KDOC-210 can be used in a self-pressurized system with a maximum temperature of 300 degrees (-70 degree ~ 300 degree)

Flow/pressure

Optional flow/pressure sensor, display flow and pressure on the touch screen.

Optional control flow/pressure.

One for two system

Optional one for two systems: the costis lower than one to one system.

One unit heating and cooling machine contains two circulation system, two cooling system, two heating systems, one expansion system, one electrical system.

High exothermic control

Customizable high heat control system algorithm and components.

flow reactor temperature control module.

It can be used in the flow reactor temp control system (pump, internal circulation system, control algorithm, refrigeration)

Related Products
  • Heating Cooling Circulator UC 50℃~300℃

    Heating Cooling Circulator UC 50℃~300℃

    January 11, 2018InformationHigh temp circulators, High temperature thermostats, High temperature circulators, Heating circulators, Heating thermostats, Heating circulation thermostats, Heating bath circulatorsview
  • Cryogenic Equipment -80℃~-10℃

    Cryogenic Equipment -80℃~-10℃

    January 11, 2018InformationIndustrial cryogenic treatment box Industry refrigerator Industrial freezer Industrial cryogenic box Cold treatment enclosure Metal cold treatment box Industrial cooling chest Cold treatment refrigerator Cold treatment freezer Refrigeration treview
  • Salt Fog Test Chamber

    Salt Fog Test Chamber

    April 8, 20181. Scope of application.With the rapid development of modern industrial technology, the application fields of all kinds of electronic and electroplating products are becoming more and more extensive, ...view
Leave a Message Email Us

we will contact you within 24 hours.

x
Want some help from our team? LNEYA is dynamic temperature control equipment leader in China. We’ll contact you very soon.
Brilliant Features of LNEYA Dynamic Temperature Control System:
Contact us and we will offer the most suitable solution for you.
  • TEL:+ 86 510 82303782
  • FAX:+ 86 510 88587187
  • EMAIL:sales@cnzlj.com
  • ADDRESS:No.10, Zhenfa No.1 Road, Shuofang Street, New District, Wuxi, Jiangsu, China