Glycol Chiller System SUNDI -10℃ ~ 200℃

Glycol Chiller System SUNDI -10℃ ~ 200℃

  • Glycol Chiller System SUNDI -10℃ ~ 200℃
  • Dynamic Temp Control Systems-2.jpg
  • Dynamic Temp Control Systems-1.jpg
Glycol Chiller System SUNDI -10℃ ~ 200℃
  • Product Description
  • System Introduce
  • Technical Parameter
  • Knowledge Center

-10℃~200℃
The system with feedforward with PV, the master PID loop operation results of the PV output and feedforward signals as the composite of the settings from the control loop, through such control of the temperature gradient, to ensure the accuracy of temperature control system.


type

Temp range℃

Heating KW

Cooling capacity  KW  AT  ℃

Flow/pressure
L/min bar

Outside size

power
KW

200

100

50

20

0

-5

SUNDI-125

-10~+200

2.5

2.5

2.5

2.5

2.5

2

1.5

20

2

400*600*1150

3.6*kw

SUNDI-125W

-10~+200

2.5

2.5

2.5

2.5

2.5

2

1.5

20

2

400*600*1150

3.6*kw

SUNDI-135

-10~+200

3.5

3.5

3.5

3.5

3.5

2.8

2.1

35

2

550*680*1450

5.6kw

SUNDI-135W

-10~+200

3.5

3.5

3.5

3.5

3.5

2.8

2.1

35

2

500*680*1250

5.6kw

SUNDI-155

-10~+200

5.5

5.5

5.5

5.5

5.5

4.4

3.3

35

2

550*680*1450

7.5kw

SUNDI-155W

-10~+200

5.5

5.5

5.5

5.5

5.5

4.4

3.3

35

2

550*680*1450

7.5kw

SUNDI-175

-10~+200

7.5

7.5

7.5

7.5

7.5

6

4.2

50

2

550*680*1450

10kw

SUNDI-175W

-10~+200

7.5

7.5

7.5

7.5

7.5

6

4.2

50

2

550*680*1450

10kw

SUNDI-1A10

-10~+200

10

10

10

10

10

8

6

75

2.5

650*700*1750

13kw

SUNDI-1A10W

-10~+200

10

10

10

10

10

8

6

75

2.5

550*680*1450

13kw

SUNDI-1A15

-10~+200

15

15

15

15

15

12

9

75

2.5

750*800*1850

20kw

SUNDI-1A15W

-10~+200

15

15

15

15

15

12

9

75

2.5

650*700*1750

20kw

SUNDI-1A25

-10~+200

25

25

25

25

25

20

15

150

2.5

1250*1000*2050

32kw

SUNDI-1A25W

-10~+200

25

25

25

25

25

20

15

150

2.5

1000*950*1750

32kw

Typical application of refrigeration heating temperature control system:

Dynamic thermostatic control of cold and heat source of high pressure reaction kettle, dynamic thermostatic control of double layer glass reaction kettle, and dynamic thermostatic control of cold and hot source of double-layer reactor.

Microchannel reactor thermostatic control, small temperature control system, steam - feeding system temperature control, material low temperature aging test.
The thermostatic control of the combined chemical cold source heat source, the cooling heating of the semiconductor equipment and the heating temperature of the vacuum chamber are controlled.

Advantages and functions of temperature control system of refrigeration:

Temperature range from 120 to 350, performance superior, unique, high - precision, intelligent temperature control.
High cooling power from 0.5 to 1200kW, highest production stability and repeatable results.
Multi-function alarm system and safety function, use plate heat exchanger, tube type heater to increase heating and cooling rate.
7-inch and 10-inch color TFT touch screen graphics display, use magnetic drive pump, no re-seal leakage problem.
Full airtight system, extended thermal conductivity liquid life, very wide temperature range, no need to change liquid media.
Ultra-high temperature cooling technology can be cooled directly from 300 degrees of high temperature.
The principle and the function has many advantages to using staff: because only expansion of cavity in the body heat conduction medium contact with oxygen in the air (and expansion tank temperature at room temperature to 60 degrees), can achieve lower heat conduction medium absorbed by oxidation and the risk of air moisture.
No heat conduction medium evaporates at high temperature, and it can be achieved -80 ~ 190 degrees, -70 ~ 220 degrees, -88 ~ 170 degrees, -55 ~ 250 degrees, -30 ~ 300 degree continuous temperature control without pressurization.


Adopt full closed pipe design, adopt high-efficiency plate heat exchanger, reducing the demand for heat conduction liquid, improve the heat utilization rate of the system, reach the rapid lifting temperature.Thermal conductive medium in a closed system, with a container, expand the heat-conducting medium not participate in circulation in the container, whether high or low temperatures, expansion tank temperature to room temperature to 60 degrees, can reduce the heat conduction medium in running the risk of absorbing the moisture and volatile.

Type

SUNDI/UST series

Control Mode

Feedback PID + Our special dynamic control calculation, Lneya PLC controller

Temp.control

Material reaction temp.control mode and jacket temp.control mode

Program Editor

10 programs, each program can edit 45 steps.

Communication Portocol

MODBUS RTU Protocol,RS485 interface

Optional  Ethernet interface/R232 interface

Temp.feedback

The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor

Material temp. feedback

Material temp. feedback:PT100 or 4~20mA or communication given

Temp.feedback:PT100

Temp. difference

Set or control oil outlet temp and reactor material temp. difference

Set or control equipment liquid inlet temp. And liquid outlet temp. Difference( keep system safe)

Material temp.accuracy

±1℃ (sometimes ±0.5℃)

Thermal medium temp. accuracy

±0.5℃

Closed circulation system

The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.

heating

 Heating max output power

 The heater has triple protection and independent temperature limiter to ensure the safety of heating system.

The power is greater than 15KW with a voltage regulator, and the heating power output control adopts 4-20ma linear control.

Cooling capacity

The power of taking away the heat at different temperature

Circulation flow rate and pressure

  Lower than 75L/min, use Lneya Magnetic pump

Higher than 75L/min use Ultra wide temperature high energy efficiency centrifugal pump.

  Pressure selection: 2bar 3bar 5bar 8bar(small power equipment can not customize)

 The greater the pressure, the greater the power of the motor, which will increase the system load and reduce the cooling capacity of the system.

compressor

Different type different brand compress

Mitsubishi, skop, Emerson, Danfoss, Italy Dorin, German blog, bizell, French Tecumseh.

evaporator

KAORI Plate heat exchanger

Oil separator

Emerson/Lneya

Drying filter

danfoss/Emerson

Shock tube

CASTEL/packless

voltage-controlled

danfoss/Emerson/fengsheng

Expansion valve

Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve.

Select different expansion valves with different temperature and cooling capacity.


Operation panel

Lneya 7-inch touch screen,show temp curve\EXCEL data output

Optional Siemens explosion - proof touch screen.(Place the operation panel outside the site area.)

optional GMP, FDA operation and record module (operator use record, data record, alarm record, etc.)

Safety protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.

refrigerant

R-404A / R404A R23 mixture/ R404A R23 R14 mixture

interface size

G1/2、G3/4、G1、DN25 DN32 DN40 DN50 DN65 DN80 DN100(PN10 RF)

Water-cooling W

 With W is water cooled type, lower than -60 degree equipment, you need use 7-25 degree cooled water

Water cooled condenser.

Tube heat exchanger, plate heat exchanger, tube condenser.

packless、sheng、KAORI、JINDIAN、XIAOLING etc

power

AC 380V 50HZ Three-phase five-wire system.  Small power 220V 50HZ single phase

Optional 460V 60HZ、220V 60HZ three-phase  

Shell material

Standard shellSUS 304,optionalspraying plastics (color 7035)

Isolation of explosion-proof

optioanl(EXdIIBT4)   

Lneya explosion-proof product installation license number.:PCEC-2017-B025

Positive pressure explosion-proof

optioanl(EXPXdmbIICT4) The positive pressure system must be water-cooled type

Lneya explosion-proof product installation license number:PCEC-2017-B025

Self pressurizing system

Optional self-pressurized 3bar system, the temperature of the system can be expanded, the expansion tank is normal pressure.

KDOC-80 can be used in a pressurized system with a maximum temperature of 250 degrees (-85 degree ~ 250 degree).

KDOC-220 can be used in the self-pressurized system with maximum temperature to 320 degrees (-50 degree ~ 320 degree).

KDOC-210 can be used in a self-pressurized system with a maximum temperature of 300 degrees (-70 degree ~ 300 degree)

Flow/pressure

Optional flow/pressure sensor, display flow and pressure on the touch screen.

Optional control flow/pressure.


One for two system

Optional one for two systems: the costis lower than one to one system.

One unit heating and cooling machine contains two circulation system, two cooling system, two heating systems, one expansion system, one electrical system.

High exothermic control

Customizable high heat control system algorithm and components.

flow reactor temperature control module.

It can be used in the flow reactor temp control system (pump, internal circulation system, control algorithm, refrigeration)

Glycol Chiller System SUNDI -10℃ ~ 200℃, as we can tell from its name, it is to use Glycol as the refrigeration agent for the chiller.

In the all air environment, because of the low temperature in the outdoors, it is impossible to use a cooling tower to supply the inner area directly with the cold air-conditioner. In addition, the cold air in the outdoors could be used directly as refrigerator source,with glycol as refrigerant, it can introduce the natural cold air into the inner area and supply cold air-conditioner. If we need to heat the outer area and provide cooling for the inner area, we can turn off the chiller and still use the boiler or the urban hot water as the heat source to heat the outer area.

Refrigeration principle of glycol chiller system

Install plate heat exchanger in the outdoor, and the outdoor cold air is introduced into the plate heat exchanger by the fan. The glycol solution and the outdoor cold air are exchanged in the plate heat exchanger. The cooled glycol solution enters into the air conditioners in the inner area and exchange with mixed air. Then the mixed air enters into the inner room with lower temperature and supply cooling. The temperature of glycol solution rise up, it comes back to the plant heat exchanger in the outdoor again, exchange heat with the cold air in the outdoor and continue this cycling after the temperature is lowered.  This way of heat exchange is usually used in the heat recycling system.

It is a very energy-saving way that use glycol as a refrigerant to introduce the cold air in the outdoors to supply cooling for the inner area. All we need to do is to install a plant heat exchanger in the outdoor when it works, the cold water equipment closed, opening the fan and the air conditioners can bring cooling for the inner area. In this way, we can save energy and reduce the cost.
Related Products
Leave a Message Email Us

we will contact you within 24 hours.

x
Want some help from our team? LNEYA is dynamic temperature control equipment leader in China. We’ll contact you very soon.
Brilliant Features of LNEYA Dynamic Temperature Control System:
Contact us and we will offer the most suitable solution for you.
  • TEL:+ 86 510 82303782
  • FAX:+ 86 510 88587187
  • EMAIL:sales@cnzlj.com
  • ADDRESS:No.10, Zhenfa No.1 Road, Shuofang Street, New District, Wuxi, Jiangsu, China