Wuxi Guanya Refrigeration technology co., ltd
Tel: + 86 510 82303782
E-mail: sales@cnzlj.com
Add: No.10, Zhenfa No.1 Road, Shuofang Street, New District, Wuxi, Jiangsu, China
code chat
High-Low Temp. Humid Heat Laboratory

High-Low Temp. Humid Heat Laboratory

High-Low Temp. Humid Heat Laboratory
  • Product Description
  • System Introduce

Product use:

High and low temperature low pressure test chamber is mainly used in aviation, aerospace, information, electronics and other fields, instruments and meters, electric products, materials, parts, equipment at the same time in the low pressure, high temperature, low temperature single or under the action of the environmental adaptability and reliability of the test, and or electric performance parameters for the specimen electricity measurement.

Box structure:

The high and low temperature low-pressure test box is made of CNC machine tool, which is beautiful and easy to operate.
The inside of the box is made of circular barrel, with air duct and heat exchanger inside, and the radiation layer and heat sink are installed to improve the low-pressure heat transfer.

Control system:

Siemens PLC+ Siemens touch screen control system, wincc configuration software.

Refrigeration system:

Using the imported brand compressor self-folding refrigeration technology, it can achieve -75 degree ~ 200 degree interval temperature control, the internal heat exchanger, hot sink plate and the radiation layer are used to refrigerate, and the heat conduction oil is used.

Circulatory system:

Using the secondary circulation system, the magnetic pump carries the circulating oil.

Technical parameters:

Temperature range

(-40℃、-70℃)~ +100℃

Humidity range

25%R.H ~95%R.H

Temperature fluctuation

±0.5℃

Rate Of Rise and Fall

0.5℃/min~10℃/min


Volume

Studio size

Outside Size

Appearance of Size

The Gate Size

6m3

1600×1800×2000

1950×2550×2380

1950×(3150~3750)×2380

1000×2000

8m3

2000×2000×2000

2350×2750×2380

2350×(3350~3950)×2380

1000×2000

10m3

2000×2500×2000

2350×3250×2380

2350×(3850~4450)×2380

1000×2000

11m3

2800×2000×2000

3150×2750×2380

3150×(3350~3950)×2380

1000×2000

12m3

3000×2000×2000

3350×2750×2380

3350×(3350~3950)×2380

1000×2000

14m3

2700×2300×2300

3050×3050×2680

3050×(3650~4250)×2650

1000×2000

16m3

4000×2000×2000

4350×2750×2380

4350×(3350~3950)×2380

1000×2000

20m3

3000×3000×2200

3350×3750×2580

3350×(4350~4950)×2580

1600×2000

24m3

3000×2500×2500

3350×3250×2880

3350×(3850~4450)×2880

1600×2000

29m3

3000×3200×3000

3350×3950×3380

3350×(4550~5150)×3380

1600×2000

32m3

4200×3200×2200

4550×3950×2580

4550×(4550~5150)×2580

2000×2000

36m3

4000×3000×3000

4350×3750×3380

4350×(4350~4950)×3380

2000×2500

40m3

3600×4400×2500

3950×5150×2880

3950×(5750~6350)×2880

2000×2500

66m3

4200×8000×2000

4550×8750×2380

4550×(9350~10250)×2380

3000×2000

Product overview:

1. It has wide temperature control range, which can meet the needs of users.

2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control can be carried out; The temperature is displayed by touch screen, easy to read, precise and convenient.

3. The temperature error can be adjusted to meet your more accurate test conditions.

4. It has the function of automatically selecting the running refrigeration circuit with the setting of temperature, and the operation is simple.

5. with functions of high temperature on, can be in when the temperature in the oven to 100 ℃, can open the refrigerator, facilitate continuous round-trip experiment was carried out between the high temperature and low temperature.

6. Self-diagnosis function, overload protection of refrigerator, high pressure switch, overload relay, thermal protection device, etc., to ensure the safety of use.

7. Use the multi-wing fan to supply the wind with strong air circulation and avoid any dead Angle, so that the temperature can be evenly distributed in the test area.

8. Wind circulation is designed with wind return wind. The wind pressure and wind speed are in accordance with the test standard.

9. Temperature rise, cooling and system complete independence can improve efficiency, reduce test cost, increase life span and reduce failure rate.

10. The water tank is placed in the lower right part of the control box, and there is water shortage and automatic protection, which facilitates the operator to replenish the water supply.

11. The humidification system pipeline is separated from the control circuit board, which can avoid the failure of water leakage in the humidified pipeline and improve the safety.

12. The piping system of the waterway system is opened by door to facilitate maintenance and repair.

13. In refrigeration system, air cooling or water cooling is adopted in condensation.

14. The test unit needs to undergo a specific temperature change curve and record the change of temperature.The range of temperature varies from -40 to 100 degrees.

15. When conducting tolerance tests, it is usually carried out in an infinite loop.

16. The temperature of the antifreeze is from -45 to 100 degrees.

17. Very steep temperature gradient changes.

18. Visualization, data storage and reporting analysis.

19. The temperature control device can be flexibly connected with other test platforms.

20. Equipped with a strong circulating pump, while ensuring the delivery of high viscosity liquids.

21. Adopt proportional control valve to control the flow output, and achieve a high precision control of 10% ~ 100% of the total range.

22. The ethylene glycol refrigeration heating system USES a fully closed circulation system, thus avoiding the opportunity of the antifreeze and outside air contact to ensure that there is no condensation of water vapor.After the expansion tank is protected by nitrogen, the temperature range of the conductive liquid will also be widened because its boiling point has been promoted.In addition, the oxidation of oxygen in the heat conducting liquid and the environment is also avoided, thus extending the service life of the thermal conductivity liquid.

23. Accurate temperature control is especially important for the repeatability and accuracy of test results.Siemens PLC control system was adopted.The electrical control part basically does not require human intervention to complete all control.Because of this high automation, there is very little manpower required to withstand testing.

24. High operational security is provided.The newly added security measures ensure a continuous unattended operation.All relevant running state data is continuously monitored and visualized on the touch screen.

The large color screen of Siemens 7 provides clear and comprehensive data information, which contains important information such as data, chart lines and annotations.The touch interface optimizes the availability of the device.Multi-level users can be implemented through password protection.The specified operator has limited permissions and can only accept Settings.This avoids accidental modification and misoperation of parameters.The operation is continuously monitored.Warnings and failures are clearly displayed and the system shuts down automatically when necessary.Faults can be tracked, so testing doesn't have to be done from scratch.At this point, the existing records are called.The system has a variety of data and communication channels, which can be adjusted according to specific applications.The temperature control unit can also be remotely controlled via the network or contained in a control system.

Related Products
  • Industrial Process Chiller SUNDI -25℃ ~ 200℃ for two reactors

    Industrial Process Chiller SUNDI -25℃ ~ 200℃ for two reactors

    January 11, 2018InformationCooling and heating temperature control system Jacket dynamic temperature control system Cooling and heating device Cooling and heating circulator Refrigeration heating circulator Refrigeration heating device Low and high temperature bath Refriview
  • Low Temperature Chiller LN -60℃~-10℃

    Low Temperature Chiller LN -60℃~-10℃

    January 11, 2018InformationLow circulator, Low temp circulator, Constant temp circulator, Low circulator, Low temp, circulation bath, Circulators bath, Circulation bath, Circulators, Chiller, Cooling circulators, Cooling bath circulators, Cooling thermostat, Refrigeratioview
  • Thermostatic Bath SC -50 /-100 ℃

    Thermostatic Bath SC -50 /-100 ℃

    January 11, 2018InformationRefrigerationSystem 1.Singlecompressorcascaderefrigerationtechnology. 2.Fastercoolingspeed,energysaving,highefficient,lownoise. 3.Famousbrandcompressor.view
Leave a Message Email Us

we will contact you within 24 hours.

  • TEL:+ 86 510 82303782
  • FAX:+ 86 510 88587187
  • EMAIL:sales@cnzlj.com